HYDRO CZĘŚCI JAKUBIEC SPÓŁKA JAWNA
Kapitałowa 4
35-213 Rzeszów

Call us:
+48 17 229 37 05

NIP: 8133391713

Hydraclamps and Side Shift Locks – JCB 3CX/4CX

Stable rear boom operation. We offer complete hydraclamps (side shift clamps), housings, piston seals, solenoids, and lock control valves. Parts from Azeri Parts, OEM, and JCB Originals.

Application: JCB 3CX, 4CX backhoe loaders (Kingpost system) and JCB mini excavators.

Play Elimination
Reinforced Solenoids
Azeri Parts & OEM
⚠️ Boom moving loosely or stuck? Crucial! Sideways play means worn hydraclamp seals. Stuck boom means solenoid/valve failure. Describe the issue – we'll match the parts.
Solve Problem

There are 21 products.

Showing 1-21 of 21 item(s)
HYDRACLAMP

How do Hydraclamps work?

In JCB machines, the rear boom slides along the frame (Kingpost). To dig effectively, the boom must be locked in position. This is done by 4 hydraclamps (pots), which clamp onto the frame rails under hydraulic pressure. Releasing the lock (pressing the side-shift button) drops the pressure and allows movement.

Common Faults and Solutions

  • Oil leak / Boom moves by itself: Worn piston seals inside the hydraclamp housing. We offer Azeri Parts repair kits resistant to high pressure.
  • Cannot unlock (slide) the boom: Often caused by a burnt solenoid coil (responsible for pressure release) or a stuck valve in the block.
  • Cracked housing: Occurs due to mechanical impact. We stock complete, new cast iron housings.

💡 Refurbishing hydraclamps?

Usually, seals are replaced in all 4 units at once. While you're at it, check the lines and fluid level:

Frequently Asked Questions (FAQ)

How many hydraclamps are on a machine?

A standard JCB 3CX/4CX backhoe has 4 hydraclamps (2 upper and 2 lower). It is recommended to service them as a set.

Can I use a coil from another function?

Not always. Coils differ in voltage and stem dimensions. We stock dedicated side-shift lock coils (often with a specific plug).

Installation issues?

Installing hydraclamp seals requires cleanliness and precision. If you need an installation diagram or advice, write to us.